Type Shd-Gc, Mining Cable, Cu/Epr/TPU, 3/C, 15kv (ICEA S-75-381/NEMA WC-58)

Model NO.: Type SHD-GC
Material Shape: Round Wire
Range of Application: Mine
Certification: ISO9001, CCC
Brand: Boan
Rated Voltage: 15 Kv
Size: 2-4/0 AWG or Mcm
Number of Cores: 3
Trademark: DingAn or OEM
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544492100
Model NO.: Type SHD-GC
Material Shape: Round Wire
Range of Application: Mine
Certification: ISO9001, CCC
Brand: Boan
Rated Voltage: 15 Kv
Size: 2-4/0 AWG or Mcm
Number of Cores: 3
Trademark: DingAn or OEM
Specification: SGS
Origin: Jiangsu Yixing, China
HS Code: 8544492100
Type SHD-GC, Mining Cable, Cu/Epr/TPU, 3/C, 15kv (ICEA S-75-381/NEMA WC-58)
Applications

These heavy duty cables are designed for applications such as longwall shearers, continuous miners, loaders, drills, conveyors, pumps and mobile equipment where grounding conductors, a ground check conductor and metallic shielding are required.

Standards

ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
CAN/CSA-C22.2 No.96

Construction

Conductors: Stranded annealed tinned copper conductor.
Insulation: Ethylene Propylene Rubber (EPR).
Insulation Shield: Tinned copper/textile braid.
Ground Check Conductor: Tinned copper conductor with a yellow polypropylene insulation.
Grounding Conductor: Tinned copper conductor.
Jacket: Reinforced extra-heavy-duty Chlorinated Polyethylene (CPE), black.

Options
Other jacket materials such as CSP/PCP/NBR/PVC/TPU are available upon request.

Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties

Minimum Bending Radius: 6×OD
Maximum Conductor Operating Temperature: +90ºC
Constructon No. of Strands Grounding Conductor Size Control Conductor Size Nominal Insulaton Thickness Nominal Jacket Thickness Nominal Overall Diameter Nominal Weight Ampacity
No. of cores×AWG/kcmil
AWG/kcmil AWG/kcmil inch inch inch lbs/kf A
3×2 259 6 8 0.21 0.235 2.41 3145 164
3×1 259 5 8 0.21 0.235 2.52 3567 187
3×1/0 266 4 8 0.21 0.250 2.64 3976 215
3×2/0 323 3 8 0.21 0.250 2.73 4526 246
3×3/0 418 2 8 0.21 0.265 2.9 5231 283
3×4/0 532 1 8 0.21 0.265 3.05 6033 325

Type SHD-GC, Mining Cable, Cu/Epr/TPU, 3/C, 15kv (ICEA S-75-381/NEMA WC-58)
Applications

These heavy duty cables are designed for applications such as longwall shearers, continuous miners, loaders, drills, conveyors, pumps and mobile equipment where grounding conductors, a ground check conductor and metallic shielding are required.

Standards

ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
CAN/CSA-C22.2 No.96

Construction

Conductors: Stranded annealed tinned copper conductor.
Insulation: Ethylene Propylene Rubber (EPR).
Insulation Shield: Tinned copper/textile braid.
Ground Check Conductor: Tinned copper conductor with a yellow polypropylene insulation.
Grounding Conductor: Tinned copper conductor.
Jacket: Reinforced extra-heavy-duty Chlorinated Polyethylene (CPE), black.

Options
Other jacket materials such as CSP/PCP/NBR/PVC/TPU are available upon request.

Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties

Minimum Bending Radius: 6×OD
Maximum Conductor Operating Temperature: +90ºC
Constructon No. of Strands Grounding Conductor Size Control Conductor Size Nominal Insulaton Thickness Nominal Jacket Thickness Nominal Overall Diameter Nominal Weight Ampacity
No. of cores×AWG/kcmil
AWG/kcmil AWG/kcmil inch inch inch lbs/kf A
3×2 259 6 8 0.21 0.235 2.41 3145 164
3×1 259 5 8 0.21 0.235 2.52 3567 187
3×1/0 266 4 8 0.21 0.250 2.64 3976 215
3×2/0 323 3 8 0.21 0.250 2.73 4526 246
3×3/0 418 2 8 0.21 0.265 2.9 5231 283
3×4/0 532 1 8 0.21 0.265 3.05 6033 325

DongGuan BoFan Technology Co.,Ltd. , https://www.pengliandz.com

Posted on